AB135. 33. Role of trabecular metal augments for Paprosky type 3 defects in acetabular revision
Orthopaedic Session II

AB135. 33. Role of trabecular metal augments for Paprosky type 3 defects in acetabular revision

Cathleen J. O’Neil1, Stephen B. Creedon1, Stephen A. Brennan2, Fiona J. O’Mahony1, Rose Lynham1, Shane Guerin1, Rehan Gul1, James A. Harty1

1South Infirmary Victoria University Hospital, Cork, Ireland;2Bon Secours Hospital, Cork, Ireland


Background: Trabecular metal augments are one option when reconstructing bone loss during acetabular side revision surgery.

Methods: We studied 38 consecutive patients with Paprosky type 3 defects that were revised using a Trabecular Metal shell and one or more augments over a 6-year period. There were 29 Paprosky type 3A defects and 9 Paprosky type 3B defects. The mean age of the patients at time of surgery was 68.2 years (range, 48–84 years). The mean length of follow-up was 36 months (range, 18–74 months).

Results: The mean pre-operative SF12 improved from 27.7 before operation to 30.1 at the time of final follow-up (P=0.001). The mean Western Ontario and McMaster Universities Arthritis Index (WOMAC) score improved from 53 pre-operatively to a mean of 78.8 at final follow-up (P<0.0001). There was evidence of radiographic loosening in seven of the cup-augment constructs. One patient developed a deep infection requiring re-revision. Two patients required revision for aseptic loosening.

Conclusions: The use of Trabecular Metal augments in complex acetabular reconstruction is associated with good outcome in the short to medium term.

Keywords: Trabecular metal; augments; reconstruction; outcome


doi: 10.21037/map.2018.AB135


Cite this abstract as: O’Neil CJ, Creedon SB, Brennan SA, O’Mahony FJ, Lynham R, Guerin S, Gul R, Harty JA. Role of trabecular metal augments for Paprosky type 3 defects in acetabular revision. Mesentery Peritoneum 2018;2:AB135. doi: 10.21037/map.2018.AB135

Download Citation